Alarms, Errors, and Troubleshooting
Complete the following steps:
1. Enter display alarms with category pnc.
Are there any on-board alarms? If so, replace the circuit pack(s).
2. Enter display errors for category pnc.
Check for any of the following errors:
MO
FIBER-LK
SNI-BD
EXP-INTF
If one or more of the previous errors are present, proceed with
If not, look for SNI-PEER errors.
4-20
Issue 1 May 2002
Error
Type
Any
513
257–769
770,
1281,
1537,
3073,
3074,
3075,
3076,
3585,
3841,
3842
If there is one SNI circuit pack with many different SNI-PEER error
types, replace the indicated SNI circuit pack.
step