Table 22: Datalogger Settings Fields (continued)
Field name
Trigger type
Trigger level 1
File name
Overwrite
Next file number
© 2023.11
Field description
Following are the trigger types:
• No trigger(manual trigger only).
• Equaltriggers when the value of the trigger source
variable is equal to trigger level 1.
• Not equaltriggers when the value of the trigger source
variable is not equal to trigger level 1.
• Greater thantriggers when the value of the trigger source
variable is greater than trigger level 1.
• Greater than or equal to triggers when the value of the
trigger source variable is greater than or equal to trigger
level 1.
• Less thantriggers when the value of the trigger source
variable is less than trigger level 1.
• Less than or equal to triggers when the value of the
trigger source variable is less than or equal to trigger level
1.
• Rising edgetriggers when the value of the trigger source
variable rises above trigger level 1. If the trigger source is
already above trigger level 1, the trigger must first drop
below the trigger level.
• Falling edgetriggers when the value of the trigger source
variable falls below trigger level 1. If the trigger source
is already below trigger level 1, the trigger must first rise
above the trigger level.
Defines the trigger level associated with the defined trigger
type. This level is used for all single-level trigger types. The
entry in the field defines the lower trigger level for window
trigger types, such as bounds and out of bounds.
Name of the file for datalogger recording.
To turn the overwrite function on or off, click the Overwrite-
toggle button.
• On: Overwrite is enabled. A file number is not appended
to the data log file. The datalogger overwrites a previous
datalog file.
• Off: Overwrite is disabled. A file number is appended
to the log file. For each datalog, the datalog file is
incremented and the previous datalog file is not
overwritten.
The number entered in this field is appended to the initial
datalog file. Entry in the field is useful when datalogs are
previously available in the drive. The number is auto-incre-
mented with each datalog recording when the entry in Next
file number is enabled.