Application Guide | iC7 Series Motion
Default Value: NA
Unit: V
P 1.1.5 L3-L1 Line Voltage (RMS)
Description: Shows the L3-L1 line voltage (RMS).
Default Value: NA
Unit: V
P 1.1.6 Grid Voltage Imbalance
Description: Shows the grid voltage imbalance in %. A value greater than 3% may indicate grid problems.
Default Value: NA
Unit: %
P 1.1.7 Total Harmonic Distortion (THDv)
Description: Shows the total harmonic distortion of the grid voltage (THDv) in %.
Default Value: NA
Unit: %
P 1.1.12 Grid Active Power
Description: Shows the active power at the point of grid connection.
Default Value: NA
Unit: kW
Power Conversion & DC Link Status (Menu Index 2.1)
6.7.2.2
P 2.1.1 Unit Nominal Voltage
Description: Shows the nominal voltage setting as a result of the setting of parameter "2.2.1.1 Unit Voltage Class".
Default Value: 400
Unit: V
P 2.1.2 Unit Nominal Current
Description: Shows the nominal current of the unit.
Default Value: 23
Unit: A
282
| © 2023.11
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Range (\* — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Number: 9049
Access Type: Read Only
Parameter Number: 9050
Access Type: Read Only
Parameter Number: 9047
Access Type: Read Only
Parameter Number: 9046
Access Type: Read Only
Parameter Number: 9064
Access Type: Read Only
Parameter Number: 2830
Access Type: Read Only
Parameter Number: 2831
Access Type: Read Only