P 5.7.4.2 AC-brake Voltage Control Kp
Description: Set the scaling of the proportional gain of the AC-brake controller.
Default Value: 100
Unit: %
P 5.7.4.3 AC-brake Voltage Control Ti
Description: Set the scaling of the integral time of the AC-brake controller.
Default Value: 100
Unit: %
P 5.7.4.4 AC-brake Current
Description: Set the maximum allowed motor current in % of nominal motor current when AC brake is enabled.
Default Value: 100
Unit: %
Speed Control (Menu Index 5.8)
6.6.10
Speed Control Overview
6.6.10.1
Parameter group 5.8 Speed Controlcontains the settings and the readout values related to the speed controller.
198
| © 2023.11
Selection Name
Disabled
Enabled
Parameter Type: Range (0 — 500)
Data Type: REAL
Parameter Type: Range (0 — 500)
Data Type: REAL
Parameter Type: Range (0 — 150)
Data Type: REAL
Selection Description
Disables the function.
Enables the function.
Parameter Number: 4027
Access Type: Read/Write
Parameter Number: 4028
Access Type: Read/Write
Parameter Number: 4057
Access Type: Read/Write
AB318753549016en-000301 / 136R0284