Application Guide | iC7 Series Motion
P 9.4.6.2 T17 Signal Inversion
Description: Select whether the signal of the terminal is inverted.
Default Value: 0 [Non-Inverted]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 9.4.6.3 T17 Fast Debounce Filtering Time
Description: Set the fast debounce filtering time for the terminal.
Default Value: 0.00
Unit: μs
P 9.4.6.4 T17 Standard Debounce Filtering Time
Description: Set the standard debounce filtering time for the terminal.
Default Value: 5.00
Unit: ms
P 9.4.6.5 T17 Reaction Time
Description: Select the reaction time for the debounce filter.
Default Value: 0 [Standard reaction time
(1ms tick)]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 9.4.6.6 T17 Trigger Mode
© 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
Non-Inverted
Inverted
Parameter Type: Range (0.00 — 63.50)
Data Type: REAL
Parameter Type: Range (0.00 — 127.00)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Standard reaction time (1ms tick)
Fast reaction time (0.5µs tick)
Parameter Number: 2293
Access Type: Read/Write
Selection Description
The signal is not inverted.
The signal is logically inverted.
Parameter Number: 2287
Access Type: Read/Write
Parameter Number: 2034
Access Type: Read/Write
Parameter Number: 2035
Access Type: Read/Write
Selection Description
Use the digital input in the same way as
other inputs.
Enables fast reaction time for certain
event via digital input.
AB318753549016en-000301 / 136R0284 |