Danfoss iC7 Motion Series Application Manual page 199

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Description: Set the speed below which DC braking is activated.
Default Value: 0
Unit: Hz
P 5.7.2.4 DC Stop Time
Description: Set the DC stopping injection duration. The value -1 means indefinitely.
Default Value: 0
Unit: s
P 5.7.2.5 DC Stop Current
Description: Set the DC stopping current in % of nominal motor current. Applied after the drive has reached standstill.
Default Value: 0
Unit: %
Quick Stop (Menu Index 5.7.3)
6.6.9.4
P 5.7.3.1 Quick Stop Inverse Input
Description: Select an input terminal for activating the Quick Stop Inverse function.
Default Value:
Unit: -
P 5.7.3.2 Quick Stop Ramp Time
Description: Set the deceleration time for the quick stop ramp.
Default Value: 1
Unit: s
AC Brake (Menu Index 5.7.4)
6.6.9.5
P 5.7.4.1 AC Brake
Description: Enables the AC Brake.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
© 2023.11
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (-1 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 1000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Selection
Data Type: BOOL
Parameter Number: 2268
Access Type: Read/Write
Parameter Number: 2320
Access Type: Read/Write
Parameter Number: 2321
Access Type: Read/Write
Parameter Number: 212
Access Type: Read/Write
Parameter Number: 1129
Access Type: Read/Write
Parameter Number: 4026
Access Type: Read/Write