Application Guide | iC7 Series Motion
Description: Enable a position window defined by touch probe 1 first and last position for acceptance of events.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 5.18.1.2.7 Touch Probe 1 First Position
Description: Set the absolute start position of the window for touch probe 1 monitoring.
Default Value: 0
Unit: PositionUnit
P 5.18.1.2.8 Touch Probe 1 Last Position
Description: Set the absolute end position of the window for touch probe 1 monitoring.
Default Value: 0
Unit: PositionUnit
P 5.18.1.2.9 Touch Probe 1 Time Limit
Description: Set a timeout for detecting a touch probe 1 event. A fault will be raised if time runs out before a touch probe 1 event is
detected. 0 disables the time limit monitoring.
Default Value: 0
Unit: s
Touch Probe 2 (Menu Index 5.18.2)
6.6.19.2
Touch Probe 2 Status (Menu Index 5.18.2.1)
6.6.19.2.1
P 5.18.2.1.1 Touch Probe 2 Event Detected
Description: Shows that an event has been detected for touch probe 2.
Default Value: NA
Unit: -
268
| © 2023.11
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Type: Range (-2147483648 —
2147483647)
Data Type: DINT
Parameter Type: Range (-2147483648 —
2147483647)
Data Type: DINT
Parameter Type: Range (0 — 16777216)
Data Type: REAL
Parameter Type: Selection
Data Type: BOOL
Parameter Number: 872
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.
Parameter Number: 873
Access Type: Read/Write
Parameter Number: 874
Access Type: Read/Write
Parameter Number: 875
Access Type: Read/Write
Parameter Number: 892
Access Type: Read Only