Application Guide | iC7 Series Motion
Default Value: 2 [Stop, Hold to Coast]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
References (Menu Index 5.5.3.2)
6.6.7.4.2
P 5.5.3.2.1 Local Speed Ref. Source
Description: Select the speed reference source for when the drive is in local control.
Default Value: 1 [Local reference]
Unit: -
The following are the selections for the parameter.
Selection Number
1
2
3
4
5
P 5.5.3.2.2 Local Torque Ref. Source
Description: Select the torque reference source for when the drive is in local control.
Default Value: 1 [Local reference]
Unit: -
The following are the selections for the parameter.
Selection Number
1
2
© 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
Stop
Coast Stop
Stop, Hold to Coast
Parameter Type: Selection
Data Type: UINT
Selection Name
Local reference
Fieldbus reference
Reference 1 input
Reference 2 input
Preset reference
Parameter Type: Selection
Data Type: UINT
Selection Name
Local reference
Fieldbus reference
Parameter Number: 110
Access Type: Read/Write
Selection Description
Push stop button to stop the motor.
Push stop button to coast the motor.
Push stop button to stop. If pressed for 2 s,
motor coasts.
Parameter Number: 1912
Access Type: Read/Write
Selection Description
Use local reference from the control panel.
Use reference from the fieldbus.
Use the reference from I/O reference 1.
Use the reference from I/O reference 2.
Use reference from the preset reference.
Parameter Number: 1925
Access Type: Read/Write
Selection Description
Use local reference from the control panel.
Use reference from the fieldbus.
AB318753549016en-000301 / 136R0284 |
173