Application Guide | iC7 Series Motion
Selection Number
0
1
P 9.4.7.6 T18 Trigger Mode
Description: Select the trigger mode for the digital input.
Default Value: 0 [None]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
P 9.4.7.7 T18 Pulse Min. Frequency
Description: Set the frequency representing 0% of the signal.
Default Value: 0
Unit: Hz
P 9.4.7.8 T18 Pulse Max. Frequency
Description: Set the frequency representing 100% of the signal.
Default Value: 110000
Unit: Hz
Analog Inputs/Outputs (Menu Index 9.5)
6.10.2.4
Output T31 (Menu Index 9.5.1)
6.10.2.4.1
P 9.5.1.1 T31 Terminal Mode
Description: Select the mode for the terminal.
Default Value: 5 [Analog Output]
Unit: -
340
| © 2023.11
Selection Name
Standard reaction time (1ms tick)
Fast reaction time (0.5µs tick)
Parameter Type: Selection
Data Type: UINT
Selection Name
None
Rising Edge
Falling Edge
Both Edges
Parameter Type: Range (0 — 110000)
Data Type: REAL
Parameter Type: Range (0 — 110000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Description
Use the digital input in the same way as
other inputs.
Enables fast reaction time for certain
event via digital input.
Parameter Number: 2041
Access Type: Read/Write
Selection Description
No event trigger.
Trig event at rising edge.
Trig event at falling edge.
Trig event at both rising and falling edge.
Parameter Number: 2042
Access Type: Read/Write
Parameter Number: 2043
Access Type: Read/Write
Parameter Number: 2019
Access Type: Read/Write
AB318753549016en-000301 / 136R0284