Application Guide | iC7 Series Motion
Description: Select the input for scaling negative torque limit between 0% and 100% value defined in negative torque limit. Off equals
100%.
Default Value:
Unit: -
P 5.9.2.31 Positive Torque Limit Scale Input
Description: Select the input for scaling positive torque limit between 0% and 100% value defined in positive torque limit. Off equals
100%.
Default Value:
Unit: -
P 5.9.2.32 Speed Limit setpoint Scale Input
Description: Select the input for scaling speed limit setpoint in torque mode between 0% and 100% of parameter value. Off equals
100%.
Default Value:
Unit: -
P 5.9.2.33 Motoring Torque Limit Response
Description: Select the response for running in motoring torque limit after the time delay defined.
Default Value: 0 [No response]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
10
P 5.9.2.34 Motoring Torque Limit Delay
Description: Set the delay the drive is allowed to be in motoring torque limit before a response is issued.
Default Value:
Unit: s
© 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
No response
Info
Fault
Parameter Type: Range (0 — 65000)
Data Type: REAL
Parameter Number: 1330
Access Type: Read/Write
Parameter Number: 1333
Access Type: Read/Write
Parameter Number: 1334
Access Type: Read/Write
Parameter Number: 2361
Access Type: Read/Write
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a fault and coasts the
motor.
Parameter Number: 2358
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
231