Description: Set the offset between permanent magnet (direct axis) angle and absolute feedback angle in the electrical domain.
The offset value is summed with the feedback angle to attain the permanent magnet angle used in the control. Its correct setting is
important when running FVC+ with synchronous motors in closed loop.
Default Value: 0
Unit: °
Speed Bypass Overview
6.6.10.11
Some systems call for some output frequencies to be avoided due to, for example, mechanical resonance problems. With the parameters
of this group, a definition of the bandwidth around each of these parameters can be provided.
These parameters allow the setting of up to 4 speed bands that are avoided.
Speed Bypass (Menu Index 5.8.8)
6.6.10.12
P 5.8.8.1 Band 1, Low Limit
Description: Set the bypass hysteresis speed band, low limit.
Default Value: 0
Unit: Hz
P 5.8.8.2 Band 1, High Limit
Description: Set the bypass hysteresis speed band, high limit.
Default Value: 0
Unit: Hz
P 5.8.8.3 Band 2, Low Limit
Description: Set the bypass hysteresis speed band, low limit.
Default Value: 0
Unit: Hz
P 5.8.8.4 Band 2, High Limit
Description: Set the bypass hysteresis speed band, high limit.
Default Value: 0
Unit: Hz
P 5.8.8.5 Band 3, Low Limit
Description: Set the bypass hysteresis speed band, low limit.
© 2023.11
Parameter Type: Range (0 — 360)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Number: 9017
Access Type: Read/Write
Parameter Number: 4520
Access Type: Read/Write
Parameter Number: 4521
Access Type: Read/Write
Parameter Number: 4522
Access Type: Read/Write
Parameter Number: 4523
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |