Danfoss iC7 Motion Series Application Manual page 179

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Selection Number
0
2
3
4
5
P 5.5.4.1.13 FB Position Reference Logic
Description: Select how to form the position reference out of the 2 inputs when operating in fieldbus control.
Default Value: 0 [Source 1]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
5
6
7
8
P 5.5.4.1.14 FB Position Reference Toggle Input
Description: Select an input for toggling between the 2 position reference sources selected when operating in fieldbus control and
toggling logic is used. A low signal selects the first source and high signal selects the second source.
Default Value:
Unit: -
© 2023.11
Selection Name
None
Fieldbus reference
Reference 1 input
Reference 2 input
Preset reference
Parameter Type: Selection
Data Type: UINT
Selection Name
Source 1
Source 2
Sum
Subtract
Divide
Multiply
Maximum
Minimum
Toggle
Parameter Type: Selection
Data Type: UINT
Selection Description
No source selected equals a 0 value.
Use reference from the fieldbus.
Use the reference from I/O reference 1.
Use the reference from I/O reference 2.
Use reference from the preset reference.
Parameter Number: 1943
Access Type: Read/Write
Selection Description
Use value from source 1 only.
Use value from source 2 only.
Add references from source 1 and 2
together.
Subtract source 2 from source 1.
Divide source 1 with source 2.
Multiply source 1 with source 2.
Use highest value of source 1 and source
2.
Use lowest value of source 1 and source 2.
Toggle between source 1 and 2 using a
digital input.
Parameter Number: 1942
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
177

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents