Application Guide | iC7 Series Motion
Parameter Descriptions
6
Introduction to Parameter Descriptions
6.1
Reading the Parameter Table
6.1.1
The application guide includes parameter overview tables. The following descriptions explain how to read the parameters.
1
2
3
4
Figure 70: Reading the Parameter Table
1
The parameter index and name. Parameter indices start
with a P.
3
The default setting from the factory.
5
The data type of the parameter. See
Data
Types.
7
The access type of the parameter. See
Access
Types.
Understanding Data Types
6.1.2
The following table is an overview of the data types used in the iC7 application software.
Table 30: Overview of data types
Data type
Description
BOOL
Boolean
INT
Integer
DINT
Double integer
USINT
Unsigned short integer
UINT
Unsigned integer
UDINT
Unsigned double integer
REAL
Real numbers
WORD
Bit string of length 16
STRING
Sequence of characters
96
| © 2023.11
5
7
6
2
4
6
6.1.2 Understanding
8
6.1.4 Understanding
Size
(Bits)
1
16
32
8
16
32
32
16
N/A
8
The parameter help text which is visible in the control
panel and MyDrive® Insight.
The unit of the parameter.
The type of parameter. Parameters have either defined
ranges of values or selections. See
Parameter
Types.
The unique parameter number, which is relevant for PLC
programming.
Range
0–1
-32,768 ... 32,767
-2,147,483,648 ... 2,147,483,647
0–255
0–65,535
0–4,294,967,295
-3.402823466 E+38 (approximately 7 digits) ...
-1,175494351 E-38 (approximately 7 digits) and
+1.175494351 E-38 (approximately 7 digits) ...
+3.402823466 E+38 (approximately 7 digits)
0–65,535 (16#00–16#FFFF)
1 byte per character
AB318753549016en-000301 / 136R0284