Application Guide | iC7 Series Motion
Load (Menu Index 5.3)
6.6.5
Load Status (Menu Index 5.3.1)
6.6.5.1
P 5.3.1.1 Inertia Estimation Status
Description: Shows the status of the inertia estimation routine. 0 = Inactive, 1 = In progress, 2 = Completed successfully, 3 = Completed
unsuccessfully.
Default Value: NA
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
Inertia (Menu Index 5.3.2)
6.6.5.2
P 5.3.2.1 Inertia Estimation Mode
Description: Set the mode for the intertia estimation.
Default Value: 0 [Off]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
P 5.3.2.2 Inertia Estimation Timeout
Description: Set the time after which an event message will be generated if inertia estimation cannot be finalized.
Default Value: 900
Unit: s
© 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
Inactive
In progress
Completed successfully
Completed unsuccessfully
Parameter Type: Selection
Data Type: UINT
Selection Name
Off
Without load profile
With load profile
Parameter Type: Range (120 — 1800)
Data Type: REAL
Parameter Number: 666
Access Type: Read Only
Selection Description
Parameter Number: 668
Access Type: Read/Conditional Write
Selection Description
The feature is disabled.
The next start command intiates a test
sequence - Without speed dependent
load.
The next start command initiates a test
sequence - With speed dependent load.
Parameter Number: 669
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |