Danfoss iC7 Motion Series Application Manual page 166

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Selection Number
0
2
4
9
10
Live Zero (Menu Index 5.2.15)
6.6.4.9
P 5.2.15.2 Live Zero Response
Description: Select the drive response to a missing input signal (live zero).
Default Value: 3 [Warning]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
3
10
Feedback Handling (Menu Index 5.2.16)
6.6.4.10
P 5.2.16.1 Failure Handling Response
Description: Select the drive response to an encoder/resolver failure.
Default Value: 10 [Coast]
Unit: -
The following are the selections for the parameter.
Selection Number
3
9
10
164
| © 2023.11
Selection Name
No response
Info
Warning - Persistent
Fault, ramp to coast
Fault
Parameter Type: Selection
Data Type: UINT
Selection Name
No Action
Info
Warning
Fault
Parameter Type: Selection
Data Type: UINT
Selection Name
Switch to Open Loop and Continue
Switch to Open Loop and Ramp to Stop
Coast
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a warning that stays
active until acknowledged by a reset.
Issues a fault, ramps down, and coast.
The drive issues a fault and coasts the
motor.
Parameter Number: 4555
Access Type: Read/Write
Selection Description
The event will be ignored.
The event is logged in the event log.
The drive issues a fault.
Parameter Number: 4600
Access Type: Read/Write
Selection Description
The drive switches to open loop operation
and continues running.
The drive switches to open loop operation
and ramps down to stop.
The drive coasts the motor.
AB318753549016en-000301 / 136R0284

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iC7 Motion Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents