Danfoss iC7 Motion Series Application Manual page 216

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Selection Number
4
0
1
2
3
5
P 5.8.6.1.2 Ramp Selection Bit 0 Input
Description: Select the digital input used as bit 0 addressing the speed ramp.
Default Value:
Unit: -
P 5.8.6.1.3 Ramp Selection Bit 1 Input
Description: Select the digital input used as bit 1 addressing the speed ramp.
Default Value:
Unit: -
Ramp 1 (Menu Index 5.8.6.2)
6.6.10.9.3
P 5.8.6.2.1 Ramp 1 Type
Description: Select the ramp type.
Default Value: 0 [Linear Ramp]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 5.8.6.2.2 Ramp 1 Accel. Time
Description: Set the acceleration time from 0 to nominal motor speed.
214
| © 2023.11
Selection Name
Bit Selection
Ramp 1
Ramp 2
Ramp 3
Ramp 4
Variable Ramp.
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
Linear Ramp
S-Ramp
Selection Description
Use digital inputs to select ramp.
Use ramp 1.
Use ramp 2.
Use ramp 3.
Use ramp 4.
Parameter Number: 1130
Access Type: Read/Write
Parameter Number: 1131
Access Type: Read/Write
Parameter Number: 1125
Access Type: Read/Write
Selection Description
Use linear ramp.
Use S-ramp ramp reducing torque
changes.
AB318753549016en-000301 / 136R0284

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents