Application Guide | iC7 Series Motion
Description: Select the input for scaling the output current limit between 0% and 100% value as defined in the current limit. Off equals
100%.
Default Value:
Unit: -
P 2.2.1.13 Output Current Limit Response
Description: Select the desired response for running in current limit after the time delay set.
Default Value: 0 [No response]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
10
P 2.2.1.14 Output Current Limit Delay
Description: Set the delay before the selected response is triggered after the drive has reached the current limit.
Default Value:
Unit: s
P 2.2.1.15 Power Limit Motor Response
Description: Select the response for running within power limit after the time delay set.
Default Value: 0 [No response]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
10
106
| © 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
No response
Info
Fault
Parameter Type: Range (0 — 65000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
No response
Info
Fault
Parameter Number: 1322
Access Type: Read/Write
Parameter Number: 2359
Access Type: Read/Write
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a fault and coasts the
motor.
Parameter Number: 2360
Access Type: Read/Write
Parameter Number: 2366
Access Type: Read/Write
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a fault and coasts the
motor.
AB318753549016en-000301 / 136R0284