Application Guide | iC7 Series Motion
Default Value: 5
Unit: s
P 5.8.6.2.3 Ramp 1 Decel. Time
Description: Set the deceleration time from nominal motor speed to 0.
Default Value: 5
Unit: s
P 5.8.6.2.4 S-Ramp 1 Accel. Increase Time
Description: Set the ramp acceleration increase time for S-ramp.
Default Value: 1
Unit: s
P 5.8.6.2.5 S-Ramp 1 Accel. Decrease Time
Description: Set the ramp acceleration decrease time for S-ramp.
Default Value: 1
Unit: s
P 5.8.6.2.6 S-Ramp 1 Decel. Increase Time
Description: Set the ramp deceleration increase time for S-ramp.
Default Value: 1
Unit: s
P 5.8.6.2.7 S-Ramp 1 Decel. Decrease Time
Description: Set the ramp deceleration decrease time for S-ramp.
Default Value: 1
Unit: s
Ramp 2 (Menu Index 5.8.6.3)
6.6.10.9.4
P 5.8.6.3.1 Ramp 2 Type
Description: Select the ramp type.
Default Value: 0 [Linear Ramp]
Unit: -
© 2023.11
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Number: 1101
Access Type: Read/Write
Parameter Number: 1105
Access Type: Read/Write
Parameter Number: 1109
Access Type: Read/Write
Parameter Number: 1113
Access Type: Read/Write
Parameter Number: 1117
Access Type: Read/Write
Parameter Number: 1121
Access Type: Read/Write
Parameter Number: 1126
Access Type: Read/Write