Selection Number
5
8
P 5.5.5.2.5 I/O Torque Reference Logic
Description: Select how to form the torque reference out of the 2 sources when operating in I/O control.
Default Value: 0 [Source 1]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
5
6
7
P 5.5.5.2.12 I/O Position Reference
Description: Select the position reference sources for when the drive operates in I/O control. Define multiple entries for combining
several sources into 1 reference value.
Default Value: [5,0]
Unit: -
The following are the selections for the parameter.
Selection Number
0
2
3
© 2023.11
Selection Name
Preset reference
Process ctrl. reference
Parameter Type: Selection
Data Type: UINT
Selection Name
Source 1
Source 2
Sum
Subtract
Divide
Multiply
Maximum
Minimum
Parameter Type: Selection
Data Type: UINT
Selection Name
None
Fieldbus reference
Reference 1 input
Selection Description
Use reference from the preset reference.
Use reference from the process control
reference.
Parameter Number: 1917
Access Type: Read/Write
Selection Description
Use value from source 1 only.
Use value from source 2 only.
Add references from source 1 and 2
together.
Subtract source 2 from source 1.
Divide source 1 with source 2.
Multiply source 1 with source 2.
Use highest value of source 1 and source
2.
Use lowest value of source 1 and source 2.
Parameter Number: 1947
Access Type: Read/Write
Selection Description
No source selected equals a 0 value.
Use reference from the fieldbus.
Use the reference from I/O reference 1.
AB318753549016en-000301 / 136R0284 |
181