Application Guide | iC7 Series Motion
Selection Number
0
3
4
P 9.4.7.2 T18 Signal Inversion
Description: Select whether the signal of the terminal is inverted.
Default Value: 0 [Non-Inverted]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 9.4.7.3 T18 Fast Debounce Filtering Time
Description: Set the fast debounce filtering time for the terminal.
Default Value: 0.00
Unit: μs
P 9.4.7.4 T18 Standard Debounce Filtering Time
Description: Set the standard debounce filtering time for the terminal.
Default Value: 5.00
Unit: ms
P 9.4.7.5 T18 Reaction Time
Description: Select the reaction time for the debounce filter.
Default Value: 0 [Standard reaction time
(1ms tick)]
Unit: -
The following are the selections for the parameter.
© 2023.11
Selection Name
Inactive
Digital input
Pulse input
Parameter Type: Selection
Data Type: UINT
Selection Name
Non-Inverted
Inverted
Parameter Type: Range (0.00 — 63.50)
Data Type: REAL
Parameter Type: Range (0.00 — 127.00)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Description
The terminal is configured as boolean
input (true/false).
The terminal is configured as pulse input.
The frequency represents an analog value.
Parameter Number: 2294
Access Type: Read/Write
Selection Description
The signal is not inverted.
The signal is logically inverted.
Parameter Number: 2288
Access Type: Read/Write
Parameter Number: 2039
Access Type: Read/Write
Parameter Number: 2040
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |