Application Guide | iC7 Series Motion
Selection Number
6
7
8
P 5.5.6.2.3 Adv. Speed Reference Toggle Input
Description: Select an input for toggling between the 2 speed reference sources selected, when operating in advanced control and
toggling logic is used. A low signal selects the 1st source and high signal selects the 2nd source.
Default Value:
Unit: -
P 5.5.6.2.4 Adv. Torque Reference
Description: Select the torque reference sources for when the drive operates in advanced control. Select 2 sources to combine them into
1 reference value.
Default Value: [2,0]
Unit: -
The following are the selections for the parameter.
Selection Number
0
2
3
4
5
8
P 5.5.6.2.5 Adv. Torque Reference Logic
Description: Select how to form the torque reference out of the 2 inputs when operating in advanced control.
Default Value: 0 [Source 1]
Unit: -
The following are the selections for the parameter.
188
| © 2023.11
Selection Name
Maximum
Minimum
Toggle
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
None
Fieldbus reference
Reference 1 input
Reference 2 input
Preset reference
Process ctrl. reference
Parameter Type: Selection
Data Type: UINT
Selection Description
Use highest value of source 1 and source
2.
Use lowest value of source 1 and source 2.
Toggle between source 1 and 2 using a
digital input.
Parameter Number: 1941
Access Type: Read/Write
Parameter Number: 1929
Access Type: Read/Write
Selection Description
No source selected equals a 0 value.
Use reference from the fieldbus.
Use the reference from I/O reference 1.
Use the reference from I/O reference 2.
Use reference from the preset reference.
Use reference from the process control
reference.
Parameter Number: 1919
Access Type: Read/Write
AB318753549016en-000301 / 136R0284