Application Guide | iC7 Series Motion
Description: Select the output terminal for controlling the mechanical brake.
Default Value:
Unit: -
P 5.12.2.2 Brake Priming Torque
Description: Set the torque to be build up against the mechanical brake during priming before releasing the brake.
Default Value: 100
Unit: %
P 5.12.2.3 Brake Priming Direction
Description: Select the direction of the applied torque during priming before releasing the brake.
Default Value: 0 [Clockwise]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
P 5.12.2.4 Brake Priming Time
Description: Set the priming time duration.
Default Value: 0.2
Unit: s
P 5.12.2.5 Brake Priming Timeout
Description: Set the time after which a warning will be generated if priming cannot be finalized.
Default Value: 5
Unit: s
240
| © 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 — 200)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Clockwise
Counter clockwise
Reference Direction
Parameter Type: Range (0 — 5)
Data Type: REAL
Parameter Type: Range (2 — 10)
Data Type: REAL
Parameter Number: 3007
Access Type: Read/Write
Parameter Number: 3012
Access Type: Read/Write
Parameter Number: 3001
Access Type: Read/Write
Selection Description
Holding torque is applied in clockwise
direction prior to opening the brake.
Holding torque is applied in counter
clockwise direction prior to opening the
brake.
Holding torque is applied in same
direction as the reference prior to opening
the brake.
Parameter Number: 3000
Access Type: Read/Write
Parameter Number: 3006
Access Type: Read/Write