Application Guide | iC7 Series Motion
Default Value: 1.21
Unit: Ω
P 4.2.4.3 d-axis Inductance Ld
Description: Set the motor non-saturated d-axis inductance. Overwritten by AMA.
Default Value: 23.00
Unit: mH
P 4.2.4.4 d-axis Inductance LdSat
Description: Set the motor saturated d-axis inductance. Overwritten by AMA.
Default Value: 23.00
Unit: mH
P 4.2.4.5 Ld Saturation Point
Description: Set the point (in % of nominal motor current) at which the Ld inductance saturates (average of non-saturated and
saturated). Overwritten by AMA.
Default Value: 100
Unit: %
P 4.2.4.6 q-axis Inductance Lq
Description: Set the motor non-saturated q-axis inductance. Overwritten by AMA.
Default Value: 85.00
Unit: mH
P 4.2.4.7 q-axis Inductance LqSat
Description: Set the motor saturated q-axis inductance. Overwritten by AMA.
Default Value: 85.00
Unit: mH
P 4.2.4.8 Lq Saturation Point
Description: Set the point (in % of nominal motor current) at which the Lq inductance saturates (average of non-saturated and
saturated). Overwritten by AMA.
134
| © 2023.11
Parameter Type: Range (0 — 1000000)
Data Type: REAL
Parameter Type: Range (0.00 — 1000.00)
Data Type: REAL
Parameter Type: Range (0.00 — 1000.00)
Data Type: REAL
Parameter Type: Range (0 — 300)
Data Type: REAL
Parameter Type: Range (0.00 — 1000.00)
Data Type: REAL
Parameter Type: Range (0.00 — 1000.00)
Data Type: REAL
Parameter Number: 408
Access Type: Read/Conditional Write
Parameter Number: 417
Access Type: Read/Conditional Write
Parameter Number: 418
Access Type: Read/Conditional Write
Parameter Number: 426
Access Type: Read/Conditional Write
Parameter Number: 427
Access Type: Read/Conditional Write
Parameter Number: 422
Access Type: Read/Conditional Write
AB318753549016en-000301 / 136R0284