Application Guide | iC7 Series Motion
Default Value: 66
Unit: %
Operation Mode (Menu Index 5.4)
6.6.6
Settings (Menu Index 5.4.2)
6.6.6.1
P 5.4.2.16 Operation Mode
Description: Select the drive operation mode.
Default Value: 0 [Speed control]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
3
5
P 5.4.2.19 Motor Feedback Mode
Description: Select the feedback mode.
Default Value: 0 [Open loop]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
© 2023.11
Parameter Type: Range (40 — 90)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Speed control
Torque control
Position control
Gear control
Parameter Type: Selection
Data Type: UINT
Selection Name
Open loop
Closed loop with Feedback Device 1
Closed loop with Feedback Device 2
Parameter Number: 8020
Access Type: Read/Write
Parameter Number: 2500
Access Type: Read/Write
Selection Description
The drive controls the motor speed.
The drive controls the motor torque.
Parameter Number: 2502
Access Type: Read/Write
Selection Description
The motor is operated without feedback.
The motor control estimates the actual
speed.
The motor is operated with feedback,
providing speed and position feedback for
motor control from feedback device 1.
The motor is operated with feedback,
providing speed and position feedback for
motor control from feedback device 2.
AB318753549016en-000301 / 136R0284 |
167