Danfoss iC7 Motion Series Application Manual page 157

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Default Value: 9 [Fault, ramp to coast]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
3
9
10
P 5.2.2.4 External Event 2 Input
Description: Select an input for the external event.
Default Value:
Unit: -
P 5.2.2.6 External Event 2 Response
Description: Select the response to an external event.
Default Value: 9 [Fault, ramp to coast]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
3
9
10
P 5.2.2.7 External Event Active Output
Description: Select an output indicating an external event.
© 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
No response
Info
Warning
Fault, ramp to coast
Fault
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
No response
Info
Warning
Fault, ramp to coast
Fault
Parameter Number: 4559
Access Type: Read/Write
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a warning.
Issues a fault, ramps down, and coast.
The drive issues a fault and coasts the
motor.
Parameter Number: 4560
Access Type: Read/Write
Parameter Number: 4562
Access Type: Read/Write
Selection Description
The event is ignored.
The event is logged in the event log.
The drive issues a warning.
Issues a fault, ramps down, and coast.
The drive issues a fault and coasts the
motor.
AB318753549016en-000301 / 136R0284 |
155

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents