Application Guide | iC7 Series Motion
Default Value: 1
Unit: kW
Additional Information for Brake Resistor
6.4.5
P 3.3.3 Brake Resistor Power Limit
The parameter must be configured to set the expected average power dissipated in the brake resistor over a period of 120 s. To calculate
the brake resistor power limit, use the following formula.
The following elements are used in the formula:
P
is the average power dissipated in the brake resistor.
l
br, avg
R
is the resistance of the brake resistor.
l
br
t
is the active breaking time within 120 s. (T
l
br
U
is the DC link when the brake chopper is active. The correct value depends on the selection of parameter 2.2.1 Unit Voltage Class
l
br
using the following table.
Table 42: Power rating and voltage class setting
Voltage range
Low voltage range
Medium voltage range
High voltage range (low brake level)
High voltage range (high brake level)
Advanced Harmonic Filter (Menu Index 3.4)
6.4.6
P 3.4.1 Advanced Harmonic Filter
Description: Select if the Advanced Harmonic Filter is connected to the drive.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 3.4.2 Capacitor Disconnect Output
Description: Select the output terminal for disconnecting the capacitor.
© 2023.11
Parameter Type: Range (0 — \*)
Data Type: REAL
).
br
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Number: 2937
Access Type: Read/Write
Unit voltage class 380–500 V AC (3N05)
705
770
780
800
Parameter Number: 3410
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.
AB318753549016en-000301 / 136R0284 |