Danfoss iC7 Motion Series Application Manual page 301

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Selection Number
9
10
P 6.4.3.3 Simulate Event Number
Description: Set the number of the event to be simulated.
Default Value: 5260
Unit: -
Automatic Reset Function
6.7.4.2
The automatic reset function enables the resetting of events without the need for a manual reset operation. This function is enabled with
parameter 6.4.4.1 Auto Reset.
When the function is enabled, a timer starts when an event requiring a reset is first triggered. An automatic reset is attempted at the end
of each time interval. If any event requiring a reset is still active, the automatic reset attempt does not succeed, and the timer continues
running. Once the maximum number of automatic reset attempts is reached, the automatic reset function stops, and a manual reset is
required to clear the events.
If all events are reset (through either an automatic or manual reset), the function resets the number of attempts and stops the timer. The
next event to trigger will begin a new cycle.
Before activating any automatic fault reset functions or changing limit values, make sure that no dangerous situations can
occur after restart. If the auto reset function is activated, the device connected to the drive output starts automatically after an
automatic fault reset.
A small set of events cannot be reset by the auto reset functionality, either because of safety reasons or because the events are
critical for the lifetime of the drive.
Auto Reset (Menu Index 6.4.4)
6.7.4.3
P 6.4.4.1 Auto Reset
Description: Enables the automatic resetting of events.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
© 2023.11
Selection Name
Response 9
Response 10
Parameter Type: Range (0 — 65535)
Data Type: UINT
  NOTICE
  NOTICE
Parameter Type: Selection
Data Type: BOOL
Selection Description
Activate occurrence response 9.
Activate occurrence response 10.
Parameter Number: 1402
Access Type: Read/Write
Parameter Number: 1405
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |