Default Value:
Unit: -
P 4.5.6 Motor Thermistor Response
Description: Select the response to a motor thermistor event.
Default Value: 9 [Fault, ramp to coast]
Unit: -
The following are the selections for the parameter.
Selection Number
3
9
10
P 4.5.7 Motor Temperature Input
Description: Select the input for the motor temperature sensor.
Default Value:
Unit: -
P 4.5.8 Motor Temperature Warning Level
Description: Set the temperature level for issuing a warning.
Default Value: 120
Unit: °C
P 4.5.9 Motor Temperature Fault Level
Description: Set the temperature level for issuing a fault. The response will be ramp down and coast.
Default Value: 150
Unit: °C
P 4.5.10 Motor Sync Loss
Description: Select the drive response if the synchronization between motor and drive is lost. This is only relevant when using a
permanent magnet or synchronous reluctance motor.
© 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
Warning
Fault, ramp to coast
Fault
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Number: 2839
Access Type: Read/Write
Parameter Number: 2846
Access Type: Read/Write
Selection Description
The drive issues a warning.
Issues a fault, ramps down, and coast.
The drive issues a fault and coasts the
motor.
Parameter Number: 2847
Access Type: Read/Write
Parameter Number: 2848
Access Type: Read/Write
Parameter Number: 2919
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
147