Application Guide | iC7 Series Motion
Description: Select the drive response to a main fan fail.
Default Value: 3 [Warning]
Unit: -
The following are the selections for the parameter.
Selection Number
3
10
P 2.2.2.4 Internal Fan Fail Response
Description: Select the drive response to an internal fan fail.
Default Value: 3 [Warning]
Unit: -
The following are the selections for the parameter.
Selection Number
3
10
Protection (Menu Index 2.3)
6.3.4
Settings (Menu Index 2.3.1)
6.3.4.1
P 2.3.1.1 Retry after Fault
Description: Enables retry functionality (ride-through) after fault.
Default Value: 1 [Enabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 2.3.1.2 Smart Derate Mode
110
| © 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
Warning
Fault
Parameter Type: Selection
Data Type: UINT
Selection Name
Warning
Fault
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Number: 2939
Access Type: Read/Write
Selection Description
The drive issues a warning.
The drive issues a fault and coasts the
motor.
Parameter Number: 2940
Access Type: Read/Write
Selection Description
The drive issues a warning.
The drive issues a fault and coasts the
motor.
Parameter Number: 2927
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.