Application Guide | iC7 Series Motion
Default Value: 100
Unit: %
Motor Control (Menu Index 4.3)
6.5.4
General Settings (Menu Index 4.3.1)
6.5.4.1
P 4.3.1.1 Motor Control Principle
Description: Select the motor control principle.
Default Value: 1 [VVC+ Control]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
P 4.3.1.2 Breakaway Current Boost
Description: Enables the breakaway current boost, which temporarily allows a higher starting current.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 4.3.1.6 Motor Feedback Test Mode
Description: Select the motor feedback test mode.
Default Value: 0 [Off]
Unit: -
The following are the selections for the parameter.
© 2023.11
Parameter Type: Range (0 — 300)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
U/f Control
VVC+ Control
FVC+ Control
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Type: Selection
Data Type: UINT
Parameter Number: 424
Access Type: Read/Conditional Write
Parameter Number: 2503
Access Type: Read/Conditional Write
Selection Description
Selects U/f control as motor control.
Selects Voltage Vector Control (VVC+) as
motor control.
Selects Flux Vector Control (FVC+) as
motor control.
Parameter Number: 2930
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.
Parameter Number: 421
Access Type: Read/Conditional Write
AB318753549016en-000301 / 136R0284 |