P 5.18.2.2.7 Touch Probe 2 First Position
Description: Set the absolute start position of the window for touch probe 2 monitoring.
Default Value: 0
Unit: PositionUnit
P 5.18.2.2.8 Touch Probe 2 Last Position
Description: Set the absolute end position of the window for touch probe 2 monitoring.
Default Value: 0
Unit: PositionUnit
P 5.18.2.2.9 Touch Probe 2 Time Limit
Description: Set a timeout for detecting a touch probe 2 event. A fault will be raised if time runs out before a touch probe 2 event is
detected. 0 disables the time limit monitoring.
Default Value: 0
Unit: s
Distance Measurement (Menu Index 5.18.3)
6.6.19.3
Distance Measurement Status (Menu Index 5.18.3.1)
6.6.19.3.1
P 5.18.3.1.1 Touch Probe Distance
Description: Shows the distance between the events at source B and source A. The value is updated at the event of source B.
Default Value: NA
Unit: PositionUnit
P 5.18.3.1.2 Touch Probe Distance Output
Description: Select an analog output to represent the distance between the events at source B and source A. The signal is scaled
between Min. Position Limit and Max. Position Limit.
Default Value:
Unit: -
272
| © 2023.11
Selection Name
Disabled
Enabled
Parameter Type: Range (-2147483648 —
2147483647)
Data Type: DINT
Parameter Type: Range (-2147483648 —
2147483647)
Data Type: DINT
Parameter Type: Range (0 — 16777216)
Data Type: REAL
Parameter Type: Range (-2147483648 —
2147483647)
Data Type: DINT
Parameter Type: Selection
Data Type: UINT
Selection Description
Disables the function.
Enables the function.
Parameter Number: 886
Access Type: Read/Write
Parameter Number: 887
Access Type: Read/Write
Parameter Number: 888
Access Type: Read/Write
Parameter Number: 896
Access Type: Read Only
Parameter Number: 808
Access Type: Read/Write