Application Guide | iC7 Series Motion
Input/Output T15 (Menu Index 9.4.4)
6.10.2.3.5
P 9.4.4.1 T15 Terminal Mode
Description: Select the mode for the terminal.
Default Value: 3 [Digital input]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
P 9.4.4.2 T15 Signal Inversion
Description: Select whether the signal of the terminal is inverted.
Default Value: 0 [Non-Inverted]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 9.4.4.3 T15 Fast Debounce Filtering Time
Description: Set the fast debounce filtering time for the terminal.
Default Value: 0.00
Unit: μs
P 9.4.4.4 T15 Standard Debounce Filtering Time
Description: Set the standard debounce filtering time for the terminal.
© 2023.11
Parameter Type: Selection
Data Type: UINT
Selection Name
Inactive
Digital Output
Pulse Output
Digital input
Pulse input
Parameter Type: Selection
Data Type: UINT
Selection Name
Non-Inverted
Inverted
Parameter Type: Range (0.00 — 63.50)
Data Type: REAL
Parameter Number: 2022
Access Type: Read/Write
Selection Description
Configures the terminal as boolean output
true/false.
Configures the terminal as analog output
based on pulse frequency.
The terminal is configured as boolean
input (true/false).
The terminal is configured as pulse input.
The frequency represents an analog value.
Parameter Number: 2295
Access Type: Read/Write
Selection Description
The signal is not inverted.
The signal is logically inverted.
Parameter Number: 2289
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
331