Danfoss iC7 Motion Series Application Manual page 350

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Ethernet port X1 (Menu Index 10.2.5)
6.11.2.5
X1 Settings (Menu Index 10.2.5.2)
6.11.2.5.1
P 10.2.5.2.5 Link Configuration X1
Description: Select the configuration of the Ethernet link parameters.
Default Value: 0 [Auto negotiation]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
Ethernet port X2 (Menu Index 10.2.6)
6.11.2.6
X2 Settings (Menu Index 10.2.6.2)
6.11.2.6.1
P 10.2.6.2.5 Link Configuration X2
Description: Select the configuration of the Ethernet link parameters.
Default Value: 0 [Auto negotiation]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
348
| © 2023.11
Parameter Type: Selection
Data Type: USINT
Selection Name
Auto negotiation
10 Mbps full duplex
10 Mbps half duplex
100 Mbps full duplex
100 Mbps half duplex
Parameter Type: Selection
Data Type: USINT
Selection Name
Auto negotiation
10 Mbps full duplex
10 Mbps half duplex
100 Mbps full duplex
100 Mbps half duplex
Parameter Number: 7048
Access Type: Read/Write
Selection Description
The drive handles the speed and duplex
settings.
10 Mbps with full duplex.
10 Mbps with half duplex.
100 Mbps with full duplex.
100 Mbps with half duplex.
Parameter Number: 7049
Access Type: Read/Write
Selection Description
The drive handles the speed and duplex
settings.
10 Mbps with full duplex.
10 Mbps with half duplex.
100 Mbps with full duplex.
100 Mbps with half duplex.
AB318753549016en-000301 / 136R0284