Danfoss iC7 Motion Series Application Manual page 60

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Table 18: Control Panel Elements Description (continued)
Legend
Name of Element
3
Converter Status Indi-
cators
4
Back button
5
REM/LOC
6
Run button
7
RUN LED
8
OFF LED
9
Stop button
10
Info button
11
Arrow buttons
12
Home/Menu button
58
| © 2023.11
Description
The LEDs indicate the status of the converter.
• [WARN]
- When this text is lit in yellow, it indicates a warning-level event.
• [READY]
- When this text is lit in white, it indicates that the converter is ready for operation.
- When this text is blinking white (1 Hz), it indicates that the converter is powered on but is
not ready.
• [FAULT]
- When this text is lit in red, it indicates a fault.
The status of the converter is also indicated by the Halo, which has the same color indicators as
the converter status texts on the control panel.
Navigates to the previously viewed screen or a menu level above the current menu.
Toggles the converter between remote and local operation.
Starts the operation of the converter.
The indicator has the following states:
• On: Start command is applied and the converter is modulating.
• Off: The converter has stopped and the start command is not applied.
The indicator has the following states:
• Steadily on: The indicator is in this state because of either of the following 2 reasons:
- The converter is not modulating and is coasted.
- The stop signal is applied, output is active, and the converter is ramping down until coast
or restart. Ramp times, protections, and stopping functions prolong this state.
• Flashes for 3 seconds: Indicates that the start command is initiated, but the converter is not
able to start.
• Off: The converter is in operation, a start signal is applied, and the output is active. This also
includes ramping, running on reference, and AMA.
Note: When a fault has occurred in the converter, the LED is on though the start command is
available. If there is a fault event, and the start command is disabled and reinitiated again, the
Off LED blinks.
Stops the operation of the converter.
Provides more detailed information about an event that has occurred in the converter. Pressing
Info also shows a context sensitive help for parameters.
• Arrow buttons: Used to navigate within the different screens and menus.
• [OK]: Primarily used to confirm selections and data in the control panel display.
Toggles between Home screen and the current parameter menu, to allow quick access to key
status information during parameter setup.
AB318753549016en-000301 / 136R0284

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents