Application Guide | iC7 Series Motion
Default Value:
Unit: -
P 5.15.2.2 Synchronization Window
Description: Set a synchronization window for activating the in-sync signal. The in sync is set when the difference between follower
position and master position has been within +/- the synchronization window for the time set by synchronization window delay.
Default Value: 100
Unit: PositionUnit
P 5.15.2.3 Synchronization Window Delay
Description: Set a delay for the in-sync signal. Relates to synchronization window.
Default Value: 50.00
Unit: ms
Gear Mode Settings (Menu Index 5.15.3)
6.6.16.3
P 5.15.3.1 Sync Mode & Start Behavior
Description: Select synchronizing with or without marker correction and start behavior. This defines at which point the follower position
is locked to the master position.
Default Value: 0 [Relative Sync At Start]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
5
P 5.15.3.2 Gear Ratio Numerator
Description: Set the numerator for the gear ratio used in gear mode. Is used in combination with gear ratio denominator.
256
| © 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 —
2147483647)
Data Type: DINT
Parameter Type: Range (0.00 —
16777216000.00)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Relative Sync At Start
Relative Sync
Absolute Sync
Marker Catch Up
Marker Sync
Marker Slow Down
Parameter Number: 324
Access Type: Read/Write
Parameter Number: 325
Access Type: Read/Write
Parameter Number: 326
Access Type: Read/Write
Parameter Number: 327
Access Type: Read/Write
Selection Description
AB318753549016en-000301 / 136R0284