Danfoss iC7 Motion Series Application Manual page 141

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
P 4.3.2.12 Frequency Point 5
Description: Set the U/f curve frequency point 5.
Default Value: 50
Unit: Hz
FVC+ Settings (Menu Index 4.3.3)
6.5.4.5
P 4.3.3.1 Continuous Rs Estimation
Description: Enables Rs estimation while running, to compensate for changing operating conditions.
Default Value: 1 [Enabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 4.3.3.2 Current Controller Kp
Description: Set the scaling of the current controller nominal proportional gain.
Default Value: 100
Unit: %
P 4.3.3.3 Current Controller Ti
Description: Set the scaling of the current controller nominal integral time.
Default Value: 100
Unit: %
P 4.3.3.5 Low-speed Mode
Description: Select the motor control mode used at low speeds.
Default Value: 0 [Selected motor control]
Unit: -
The following are the selections for the parameter.
© 2023.11
Parameter Type: Range (0 — 2000)
Data Type: REAL
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Type: Range (0 — 100000)
Data Type: REAL
Parameter Type: Range (0.1 — 100000)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Number: 2615
Access Type: Read/Write
Parameter Number: 428
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.
Parameter Number: 8021
Access Type: Read/Write
Parameter Number: 8022
Access Type: Read/Write
Parameter Number: 2816
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
139