Danfoss iC7 Motion Series Application Manual page 66

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Ramp 1 Type Selector
Linear Ramp
S-Ramp
Figure 37: The Selections of a Parameter
2.
To browse through the selections, press the up or down arrow buttons.
3.
To select a selection, press OK.
Changing a Parameter Value
3.2.10
The example parameter in this procedure is P 5.8.6.2.2 Ramp 1 Accel. Time.
1.
Go to parameter 5.8.6.2.2 Ramp 1 Accel. Time and press OK.
The range of the parameter (minimum to maximum values) is shown at the bottom of the control panel display.
2.
To go to the values before or after the decimals, use the left and right arrow buttons. A black highlight on the digit indicates the
location where the cursor is active.
3.
To increase or decrease the value, press the up and down arrow buttons.
4.
Confirm the changes by pressing OK.
The following illustration shows the process of changing the value of a parameter.
1
iC7_Industry
0.0 rpm
0.0 Nm
Ramp 1
5.8.6.2.1 Ramp 1 Type Selector
Linear Ramp
5.8.6.2.2 Ramp 1 Accel. Time
5.00 s
5.8.6.2.3 Ramp 1 Decel. Time
5.00 s
Figure 38: Changing the Value of a Parameter
Locking the Control Panel Display
3.2.11
To avoid unintended interaction via the control panel, the control panel display can be locked.
To lock the control panel, press the Backbutton for 3 seconds. After 3 seconds, the following screen is shown.
iC7_Industry
Noad Drooping Frequency
Eotor Torque
3s
Dotor Shaft Power
Motor Current
Figure 39: Control Panel Lock Screen
When the control panel is locked, pressing the control panel buttons has no effect.
To unlock the control panel, press the Back button for 3 seconds.
64
| © 2023.11
2
REM
Ramp 1 Accel. Time
0.0 kW
00005.0
0
0
s
0.0
REM
0.0 Hz
0.0 Hz
0.00 Nm
0.00 kW
0.00 A
3
Ramp 1 Accel. Time
000
10.0
10.00
0
s
0.0
10000.0
AB318753549016en-000301 / 136R0284
4
iC7_Industry
LOC
0.0 rpm
0.0 Nm
0.0 kW
Ramp 1
5.8.6.2.1 Ramp 1 Type Selector
Linear Ramp
5.8.6.2.2 Ramp 1 Accel. Time
10.00 s
5.8.6.2.3 Ramp 1 Decel. Time
10000.0
5.00 s