Danfoss iC7 Motion Series Application Manual page 93

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Index
5.8.3.1
5.8.3.2
5.8.3.3
6.
Configure the ramp.
Index
5.8.6.1.1
5.8.6.2.1
5.8.6.2.2
5.8.6.2.3
7.
Configure the reference and input settings according to the selected reference type.
Table 26: Reference Settings
Index
5.8.4.1
5.8.4.3
5.8.4.4
Table 27: Basic I/O Settings
Index
9.5.2.1
9.5.2.2
9.5.2.3
9.5.2.4
8.
Optional: Configure the settings for the Auto Tuning of the speed controller.
For achieving optimal motor control performance, perform an Inertia Estimation or, if the inertia is known, enter the inertia
manually with parameter 5.3.2.3 System Inertia.
© 2023.11
Parameter name
Positive Speed Limit
Negative Speed Limit
Minimum Speed Limit
Parameter name
Ramp Selector
Ramp 1 Type
Ramp 1 Accel. Time
Ramp 1 Decel. Time
Parameter name
Speed Reference 1 Input
Speed Reference 1 Maximum
Speed Reference 1 Minimum
Parameter name
T33 Terminal Mode
T33 Terminal Type
T33 Minimum Value
T33 Maximum Value
Example setting
1500 RPM
-1500 RPM
0 RPM
Example setting
Ramp 1
Linear ramp
5 s.
5 s.
Example setting
Basic I/O T33
1500 RPM
0 RPM
Example setting
Analog input
Voltage
0 V
10 V
AB318753549016en-000301 / 136R0284 |
Parameter
number
1729
1728
1722
Parameter
number
1100
1125
1101
1105
Parameter
number
501
1724
1725
Parameter
number
2020
2273
2272
2271