Application Guide | iC7 Series Motion
Default Value:
Unit: -
P 5.2.1.2 Cooling Monitor Fault Delay
Description: Set a delay before the cooling monitor issues a fault. Only valid if fault is selected.
Default Value: 3
Unit: s
P 5.2.1.3 Cooling Monitor Response
Description: Select the response to a missing cooling monitor signal. The response is selected for both stopped and running states.
Default Value: 2 [Warning, Fault after
Timeout]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
External Event (Menu Index 5.2.2)
6.6.4.2
P 5.2.2.1 External Event 1 Input
Description: Select an input for the external event.
Default Value:
Unit: -
P 5.2.2.3 External Event 1 Response
Description: Select the response to an external event.
154
| © 2023.11
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 — 100)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
While running, Warning after Timeout
Warning
Warning, Fault after Timeout
No response/Warning, Fault after Timeout
Parameter Type: Selection
Data Type: UINT
Parameter Number: 2400
Access Type: Read/Write
Parameter Number: 2401
Access Type: Read/Write
Parameter Number: 2402
Access Type: Read/Write
Selection Description
Drive issues a warning after timeout.
Drive issues a warning immediately.
Drive issues a warning immediately. If the
drive is running the warning escalates into
a fault after timeout.
While stopped, no response is given.
While running, the drive issues a warning
immediately. The warning escalates into a
fault after timeout.
Parameter Number: 4557
Access Type: Read/Write
AB318753549016en-000301 / 136R0284