Application Guide | iC7 Series Motion
P 5.9.3.9 Preset Torque 2
Description: Set the torque preset value in % of the nominal motor torque.
Default Value: 25
Unit: -
P 5.9.3.10 Preset Torque 3
Description: Set the torque preset value in % of the nominal motor torque.
Default Value: 50
Unit: -
P 5.9.3.11 Preset Torque 4
Description: Set the torque preset value in % of the nominal motor torque.
Default Value: 100
Unit: -
P 5.9.3.12 Preset Torque Bit 0 Input
Description: Select the digital input used as bit 0 addressing the preset reference.
Default Value:
Unit: -
P 5.9.3.13 Preset Torque Bit 1 Input
Description: Select the digital input used as bit 1 addressing the preset reference.
Default Value:
Unit: -
P 5.9.3.14 Torque Reference Ramp Time
Description: Set the ramping time from 0 to nominal motor torque.
Default Value: 0
Unit: s
P 5.9.3.15 Torque Ref. Lowpass Filter Tc
Description: Set the time constant of the reference filter. Setting it to 0 disables the filter.
234
| © 2023.11
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 — 10000)
Data Type: REAL
Parameter Number: 726
Access Type: Read/Write
Parameter Number: 727
Access Type: Read/Write
Parameter Number: 728
Access Type: Read/Write
Parameter Number: 721
Access Type: Read/Write
Parameter Number: 722
Access Type: Read/Write
Parameter Number: 2330
Access Type: Read/Write
AB318753549016en-000301 / 136R0284