Application Guide | iC7 Series Motion
Selection Number
4
5
6
7
P 5.5.6.1.11 Advanced Reset Input
Description: Select inputs for resetting faults when operating in advanced control.
Default Value:
Unit: -
P 5.5.6.1.13 Advanced Start Mode
Description: Select the starting logic for advanced control.
Default Value: 0 [State High Start]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
P 5.5.6.1.15 Fieldbus CTW Feature Bits
Description: Enables non-control-place-dependent control word bits to be active in advanced control place.
Default Value: 1 [Enabled]
Unit: -
The following are the selections for the parameter.
186
| © 2023.11
Selection Name
NAND
NOR
XOR
XNOR
Parameter Type: Selection
Data Type: UINT
Parameter Type: Selection
Data Type: UINT
Selection Name
State High Start
Rising Edge Start
High Pulse Start
Parameter Type: Selection
Data Type: BOOL
Selection Description
Logically NAND source 1 and 2.
Logically NOR source 1 and 2.
Logically XOR source 1 and 2.
Logically XNOR source 1 and 2.
Parameter Number: 4731
Access Type: Read/Write
Parameter Number: 4726
Access Type: Read/Write
Selection Description
Start command remains as long as input is
true.
Start command is set when input
becomes true and remains latched until
stop command is given. Start remains
latched over stop if input is kept true.
Start command is set when input
becomes true and remains latched until
stop command is given.
Parameter Number: 4627
Access Type: Read/Write
AB318753549016en-000301 / 136R0284