Application Guide | iC7 Series Motion
P 5.9.3.4 Torque Reference 1 Min.
Description: Set the minimum torque reference value in % of nominal motor torque.
Default Value: 0
Unit: %
P 5.9.3.5 Torque Reference 2 Max.
Description: Set the maximum torque reference value in % of nominal motor torque.
Default Value: 100
Unit: %
P 5.9.3.6 Torque Reference 2 Min.
Description: Set the torque minimum reference value in % of nominal motor torque.
Default Value: 0
Unit: %
P 5.9.3.7 Preset Torque Selector
Description: Select the preset torque number.
Default Value: 1 [Preset 1]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
2
3
4
P 5.9.3.8 Preset Torque 1
Description: Set the torque preset value in % of the nominal motor torque.
Default Value: 10
Unit: -
© 2023.11
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Bit Selection
Preset 1
Preset 2
Preset 3
Preset 4
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Number: 4531
Access Type: Read/Write
Parameter Number: 4532
Access Type: Read/Write
Parameter Number: 4533
Access Type: Read/Write
Parameter Number: 724
Access Type: Read/Write
Selection Description
Use digital inputs to select the preset
reference number.
Use preset 1.
Use preset 2.
Use preset 3.
Use preset 4.
Parameter Number: 725
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
233