Application Guide | iC7 Series Motion
Default Value: 10
Unit: s
P 5.8.5.5 Freeze Ramp Delay
Description: Set the delay before ramping the reference while reference freeze is active.
Default Value: 4
Unit: s
P 5.8.5.6 Freeze Step Delta
Description: Set the reference step for increasing/decreasing the reference while reference freeze is active.
Default Value: 1
Unit: Hz
P 5.8.5.7 Freeze Initialization
Description: Enables freeze initialization. If enabled, freeze reference is initialized to the minimum speed after start-up or a start signal is
applied. If disabled, the latest value is used.
Default Value: 0 [Disabled]
Unit: -
The following are the selections for the parameter.
Selection Number
0
1
P 5.8.5.8 Freeze Ramp/Step Mode
Description: Select how to increase or decrease the reference while reference freeze is active.
Default Value: 0 [Step and Ramp]
Unit: -
The following are the selections for the parameter.
212
| © 2023.11
Parameter Type: Range (0 — 1000)
Data Type: REAL
Parameter Type: Range (0 — 3600)
Data Type: UDINT
Parameter Type: Range (0 — 1000)
Data Type: REAL
Parameter Type: Selection
Data Type: BOOL
Selection Name
Disabled
Enabled
Parameter Type: Selection
Data Type: UINT
Parameter Number: 1003
Access Type: Read/Write
Parameter Number: 1004
Access Type: Read/Write
Parameter Number: 1005
Access Type: Read/Write
Parameter Number: 1006
Access Type: Read/Write
Selection Description
Disables the function.
Enables the function.
Parameter Number: 1007
Access Type: Read/Write