Table 48: Summary Table (continued)
Group
Numb
Display Name
Numb
er
er
(Deci
(Hex)
mal)
0x448
5401
AHF High Temp. Stop
0
0x510
4641
24V Backup Mode
0
0x511
4640
24V Supply Fault
2
0x511
4642
3.3V Supply Low
4
0x511
4643
28V Supply Low
8
0x51F
4644
Gate Driver Voltage Fault
E
0x51F
4653
Gate Driver Fault
E
0x51F
4645
Power Board Supply Fault
F
0x51F
4646
Power Supply Voltage
F
0x521
4378
Current Sensor Fault
0
0x540
5173
Power Limit Timeout Re-
0
generative
0x540
5174
Power Limit Timeout Mo-
0
toring
0x548
4152
ShootThroughFaultIntAfe
0
0x54F
4647
Function Disabled
D
0x54F
4628
STO Activated
E
364
| © 2023.11
Description
A too high temperature has been detected in
the connected AHF (Advanced Harmonic Fil-
ter). Operation of the drive has been stopped.
The drive is in 24V backup mode. The control
section (including parameter configurations)
and installed options are kept operational.
The 24V supply is outside its normal operat-
ing range.
The voltage of the internal 3.3V supply is be-
low its normal operating range.
The voltage of the internal 28V supply is be-
low its normal operating range.
The gate driver supply voltage is outside its
normal operating range.
A gate driver fault is detected or a link to the
gate driver is broken.
A power supply fault on the power board has
been detected.
A power supply voltage is outside its normal
operating range.
A defective current sensor or an error in the
calibration of the current sensors has been
detected.
The drive has exceeded the allowed time in
power limit.
The drive has exceeded the allowed time in
power limit.
Converter shoot-through detected
The protection logic keeps the trip active un-
til the configuration of the power unit protec-
tion levels is ready.
The Safe Torque-Off (STO) is activated and
an unintended restart is prevented until the
STO-request has been reset.
Type of Event
Inverter and
Brake Chopper
Action
I
F
P
Invert
W
F
er
X
RC
X
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
X
C
AB318753549016en-000301 / 136R0284
Brake
C
C
C
C
C
C
C
C
C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents