P 5.12.2.6 Brake Release Time
Description: Set the time it takes for the mechanical brake to open and to release the load.
Default Value: 0.5
Unit: s
P 5.12.2.7 Brake Open Input
Description: Select the input terminal for an open indication signal from the mechanical brake.
Default Value:
Unit: -
P 5.12.2.8 Brake Hover Time
Description: Set the hover time. Hover time is the duration where the drive holds the load before the mechanical brake closes to allow
an instant restart.
Default Value: 0
Unit: s
P 5.12.2.9 Brake Closing Speed
Description: Set the speed at which the brake gets active (control terminal goes low).
Default Value: 5
Unit: Hz
P 5.12.2.10 Brake Close Time
Description: Set the time it takes for the mechanical brake to close and to hold the load.
Default Value: 0.5
Unit: s
P 5.12.2.11 Brake Closed Input
Description: Select the input terminal for a closed signal from the mechanical brake.
Default Value:
Unit: -
P 5.12.2.12 Brake Disengaging Time
Description: Set the duration from the brake is closed to the holding torque is released.
© 2023.11
Parameter Type: Range (0.1 — 30)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (0 — 60)
Data Type: REAL
Parameter Type: Range (0 — 25)
Data Type: REAL
Parameter Type: Range (0.1 — 30)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Number: 3003
Access Type: Read/Write
Parameter Number: 3010
Access Type: Read/Write
Parameter Number: 3013
Access Type: Read/Write
Parameter Number: 3002
Access Type: Read/Write
Parameter Number: 3004
Access Type: Read/Write
Parameter Number: 3011
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |