Application Guide | iC7 Series Motion
1
The name of the application software.
3
The current control of the drive. REM indicates remote
control and LOC indicates local control. The arrow shows
the direction of the motor.
5
The scroll bar. The scroll bar indicates whether the screen
is in the upper Readout Screen 1 or lower Readout Screen 2
position, when in the menu structure or parameters.
The status line of the control panel shows the status of the drive. The status line texts are dynamically generated, based on the
configuration of the system. The following are some examples of basic operation:
Table 19: Drive Status Texts
Drive status in the panel
Drive Ready
Running at Reference
Running at Standstill
Stopping
Stopped
Coasted
Quick Stop
Start Interlock
Start Inhibited
Safe Torque Off (STO)
Inching
Running/Stopping/Inching with:
• Power Limit
• Undervoltage Limit
• Overvoltage Limit
• Torque Limit
• Current Limit
• Speed Limit
AMA Ready
AMA in Progress
AMA Finished
60
| © 2023.11
2
4
6
Description
The drive is powered and ready to start.
The drive is running at the selected reference.
The drive is running with 0 reference.
The drive is running towards stop.
The drive is stopped due to an active stop command.
The drive is coasting due to an active coast command.
The drive is stopped due to an active quick stop command.
The drive is stopped with an active start command. To restart, the start command must
be removed and given again.
The drive is in a state that is preventing start. All start commands are ignored.
The drive is coasting due to an active STO command.
The drive is inching or jogging.
The drive is running, stopping, or inching, and has exceeded the limit that is shown. For
example, Running - Power Limit.
Some possible limits are listed in the cell on the left. See also the preceding image.
Advanced Motor Adaptation is activated and is waiting for the start command.
Advanced Motor Adaptation is running, measuring motor data.
Advanced Motor Adaptation is finished. To restart the drive, remove and then reapply
the start command.
The status of the drive (see the following table).
The setpoint of the selected operation mode. The local
setpoint can only be changed when the drive is in local
control.
The readout value as a donut infographic view. It is
possible to show only a single readout in a donut view.
When more than 1 readout is configured, the screen
changes to a line view. A minimum of 2 and a maximum of
5 readouts are shown in the line view.
AB318753549016en-000301 / 136R0284