Danfoss iC7 Motion Series Application Manual page 139

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Voltage
Voltage Pt 5
Voltage Pt 4
Voltage Pt 3
Voltage Pt 2
Voltage Pt 1
Freq.Pt 0 Freq.Pt 1
Figure 74: U/f Settings
U/f Settings (Menu Index 4.3.2)
6.5.4.4
P 4.3.2.1 Voltage Point 0
Description: Set the U/f curve voltage point 0.
Default Value: 8
Unit: V
P 4.3.2.2 Voltage Point 1
Description: Set the U/f curve voltage point 1.
Default Value: 80
Unit: V
P 4.3.2.3 Voltage Point 2
Description: Set the U/f curve voltage point 2.
Default Value: 160
Unit: V
P 4.3.2.4 Voltage Point 3
Description: Set the U/f curve voltage point 3.
Default Value: 240
Unit: V
P 4.3.2.5 Voltage Point 4
Description: Set the U/f curve voltage point 4.
© 2023.11
Freq.Pt 2
Freq.Pt 3
Freq.Pt 4
Frequency
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Parameter Type: Range (0 — \*)
Data Type: REAL
Freq.Pt 5
Parameter Number: 2600
Access Type: Read/Write
Parameter Number: 2601
Access Type: Read/Write
Parameter Number: 2602
Access Type: Read/Write
Parameter Number: 2603
Access Type: Read/Write
AB318753549016en-000301 / 136R0284 |
137

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic7 seriesIc7-automation

Table of Contents