Danfoss iC7 Motion Series Application Manual page 159

Hide thumbs Also See for iC7 Motion Series:
Table of Contents

Advertisement

Application Guide | iC7 Series Motion
Description: Shows the temperature measured for the temperature protection.
Default Value: NA
Unit: °C
Temp. 1 Protection (Menu Index 5.2.3.2)
6.6.4.4.2
P 5.2.3.2.1 Temp. 1 Input
Description: Select the temperature sensor input for the temperature protection.
Default Value:
Unit: -
P 5.2.3.2.2 Temp. 1 Limit 1
Description: Set the temperature level for issuing a warning.
Default Value: 120
Unit: °C
P 5.2.3.2.3 Temp. 1 Limit 2
Description: Set the temperature level for issuing a protection response.
Default Value: 150
Unit: °C
P 5.2.3.2.4 Temp. 1 Limit 2 Response
Description: Select the response for exceeding the limit.
Default Value: 9 [Fault, ramp to coast]
Unit: -
The following are the selections for the parameter.
Selection Number
3
9
10
Temp. 2 Protection (Menu Index 5.2.3.3)
6.6.4.4.3
P 5.2.3.3.1 Temp. 2 Input
© 2023.11
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Range (-300 — 300)
Data Type: REAL
Parameter Type: Selection
Data Type: UINT
Selection Name
Warning
Fault, ramp to coast
Fault
Parameter Number: 5205
Access Type: Read Only
Parameter Number: 5206
Access Type: Read/Write
Parameter Number: 5207
Access Type: Read/Write
Parameter Number: 5208
Access Type: Read/Write
Parameter Number: 5209
Access Type: Read/Write
Selection Description
The drive issues a warning.
Issues a fault, ramps down, and coast.
The drive issues a fault and coasts the
motor.
AB318753549016en-000301 / 136R0284 |
157