Risks Associated With Live Electric Parts - ABB IRB 2600 Product Manual

Hide thumbs Also See for IRB 2600:
Table of Contents

Advertisement

1 Safety

1.2.3.7 Risks associated with live electric parts

1.2.3.7 Risks associated with live electric parts
Voltage related risks, general
Work on the electrical equipment of the robot must be performed by a qualified
electrician in accordance with electrical regulations.
The necessary protection for the electrical equipment and robot system during
construction, commissioning, and maintenance is guaranteed if the valid regulations
are followed.
All work must be performed:
Voltage related risks, IRC5 controller
A danger of high voltage is associated with, for example, the following parts:
Continues on next page
30
Although troubleshooting may, on occasion, need to be carried out while the
power supply is turned on, the robot must be turned off (by setting the mains
switch to OFF) when repairing faults, disconnecting electric leads and
disconnecting or connecting units.
The mains supply to the robot must be connected in such a way that it can
be turned off from outside the working space of the robot.
Make sure that no one else can turn on the power to the controller and robot
while you are working with the system. A good method is to always lock the
main switch on the controller cabinet with a safety lock.
by qualified personnel
on machine/robot system in deadlock
in an isolated state, disconnected from power supply, and protected against
reconnection
Be aware of stored electrical energy (DC link, Ultracapacitor bank unit) in
the controller.
Units such as I/O modules, can be supplied with power from an external
source.
The mains supply/mains switch
The transformers
The power unit
The control power supply (230 VAC)
The rectifier unit (262/400-480 VAC and 400/700 VDC. Note: Capacitors!)
The drive unit (400/700 VDC)
The drive system power supply (230 VAC)
The service outlets (115/230 VAC)
The customer power supply (230 VAC)
The power supply unit for additional tools, or special power supply units for
the machining process.
The external voltage connected to the controller remains live even when the
robot is disconnected from the mains.
Additional connections.
© Copyright 2009-2015 ABB. All rights reserved.