ABB IRB 2600 Product Manual page 100

Hide thumbs Also See for IRB 2600:
Table of Contents

Advertisement

2 Installation and commissioning
2.5.1 Installation of cooling fan for motors (option)
Continued
Installation, fan on motor axis 1 and 2
Use this procedure to install the cooling fan on motor axis 1 and 2.
1
2
3
4
5
6
7
Continues on next page
100
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Remove the back plate of the fanbox.
Place the fanbox around motor axis 1 and 2.
Refit the back plate of the fanbox.
Tip
Only applicable to fan fitted on axis 1!
If there is a lack of space between motor and
robot, it is possible to remove part of the fanbox.
Push the fanbox in line with the connection box.
Fit the fanbox with two attachment screws
M6x25.
© Copyright 2009-2015 ABB. All rights reserved.
Note
See the figure in:
Cooling fan on page 99
See the figure in:
Cooling fan on page 99
See the figure in:
Cooling fan on page 99
Align the upper part of the fan with the
lower part of the connection box.
A
B C
xx1000000124
Parts:
A: Connection box
B: Position where the fan shall
be aligned with connection box
C: Fan
Product manual - IRB 2600